Volver a la información general
EPD 4.0 End Position Detector
An external end position detector to monitor the position of the two switch blades.
Volver a la información general
An external end position detector to monitor the position of the two switch blades.
The end position detector 4.0 (4th generation end position detector) is a vital monitoring device mounted next to the track on existing railway sleepers. It is designed to enhance railway safety and efficiency. It monitors the positions of both closed and open switch rails, can verify external lock positions and detects gauge changes.
It can be installed both as an end position detector with a standard setting drive system, like ECOSTAR or in combination with the drive, locking and detection (DLD) system, such as HYDROSTAR® in a high-speed track environment and UNISTAR HR in mixed track.
Trendsetting concept. During the development of the end position detector EPD 4.0, particular attention was paid to whole life costs and MTBF/ MTTR. Due to an innovative design, the main unit weighs 8 kg and has reduced height to ensure the unit is lower than top of rail (vignole designs) providing adequate clearance to the structural gauge of rolling stock. The detector is completely encapsulated and thus protected as far as possible against environmental influences.
The end position tester EPD 4.0 can be used with any standard setting, DLD system in the area of Mixed Traffic, High Speed Traffic as well as Freight Traffic and Metro lines. Due to an extensive preassembly at the manufacturer’s factory, the installation and the integration into the electrical and customers signalling system of the turnout can be carried out in a few simple steps.
Designation | Value / Type |
Turnout type | all types |
Minimum gauge of the turnout | 960 to 1678 mm |
Switch openings | 30 to 175 mm |
Main dimensions LxWxH | 280x274x125 mm |
Suitable for longitudinal movements | max. ± 40 mm |
Number of monitoring levels | max. 10 |
Overall mass | 8 kg |
Ambient temperature | -40 °C to +75°C |
Safety level / class | SIL4, according to CENELEC / EN 50125-3 / 60068 |
Protection class | up to IP67 |
Houseing material | stainless steel |